Q. Can inflammable gas be used with GF300?
A. Yes, it can be used. It can be used as long as permeation leakage is prevented by using New VALFLON (TM) Paste.
Q. Is it better to coat a gasket paste on high performance non-asbestos sheet gasket?
A. We recommend coating a gasket paste on the surface of the gasket that comes in contact with the flange and the cut surface of the gasket inside diameter side for gas seals. Also, please use the New VALFLON (TM) Paste for the gasket paste. In particular, No.6 and No.6M cannot be used because they have poor compatibility with the surface of the high performance non-asbestos sheet gasket.
Q. May hot bolting be performed on the high performance non-asbestos sheet gasket?
A. Yes, it may be performed. Performing hot bolting has an effect of maintaining the tightening force. However, a reduction of rigidity occurs at high temperatures because PTFE of the constituent materials has thermoplasticity. We therefore recommend to perform hot bolting by control of tightening force while paying attention not to cause damage by excessive tightening.
Q. Why are the GF300 Series as well as 7020 and 7026 (fluorocarbon resin gasket) described to be unsuitable for polymerizable monomers?
A. There are cases in which the polymerizable monomer causes expansion by permeating into the gasket and polymerizing inside it, which results in the gasket to be damaged. We recommend the use of a spiral wound gasket with inner & outer rings or a metallic gasket, which hardly allow polymerizable monomers to permeate, or difficult to damage even if they permeate and polymerize.
Q. Can the high performance non-asbestos sheet gasket be also used on large diameter flanges that exceed the width and length?
A. Yes, it can also be used on large diameter flanges because it can be bonded.
Q. I want to control the width of the opening in the flange such as with a sheet gasket. How should I do this?
A. Control with width of the opening in the flange is prone to cause a margin of error and an accurate tightening stress cannot be obtained. It is effective for uneven tightening, so please use it in conjunction with control of tightening torque.
Q. Please tell me about the difference in the gasket dimensions between flanges of the JPI and ASME/ANSI standards.
A. JPI basically quotes from ASME/ANSI, so there are cases in which the dimensions differ slightly due to rounding error during the millimeter conversion of the original number. We understand that, in actual use, the function of the gasket is fulfilled to an equivalent degree by both dimensions.
Q. Why does leakage occur during stop or re-operation even though there are no problems during plant operation?
A. Expansion and contraction of the flange, bolt, pipe and the like will occur due to temperature changes. As a result, a tendency of reduced tightening force in the gasket main unit is often observed when the temperature decreases (including low temperature at the time of initial re-operation), and leakage occurs due to relaxation. We therefore generally recommend a retightening of the gasket before re-operation after the first heat addition.
Q. Is retightening effective when leakage occurs?
A. Yes, it is effective. We ask that retightening during leakage be performed after relieving internal pressure. However, there are also points to keep in mind for each product, such as the possibility of damage as a result of temperature-induced hardening in the case of a compressed non-asbestos fiber sheet.
Q. I am not sure which gasket to select, so could you select it for me?
A. If you contact us together with your operating conditions, we will recommend an appropriate product based on our technician's selection.